How much air (cubic feet per minute) does a room, a system or a duct need? This calculator works it out three ways: from the room volume and the air changes per hour, from the air conditioner tonnage (400 CFM per ton), or from the BTU load and the temperature difference across the coil. It also gives the round duct size at a 900 FPM design velocity. The result is an estimate for planning — a licensed HVAC professional should confirm the final duct design.
Calculate your CFM
Air changes per hour: a bedroom is about 4–6, a kitchen or bathroom 6–8, a workshop 8–12. The 400 CFM per ton rule is the industry standard for cooling. The BTU method divides the load by 1.08 × the temperature difference — at a 25 °F difference it agrees with the 400 CFM/ton rule within 10%; at 27.8 °F they match exactly.
Your results
How the CFM formula works
CFM is cubic feet per minute — the volume of air moved in a minute. There are three standard ways to work it out, and they all describe the same air.
By room + ACH: CFM = length × width × height × ACH ÷ 60
By tonnage: CFM = tons × 400 — the standard 400 CFM per ton of cooling
By BTU: CFM = BTU/hr ÷ (1.08 × ΔT) — 1.08 is the air constant (0.018 × 60), ΔT is the temperature difference across the coil in °F
Duct size: diameter = 12 × √(4 × CFM ÷ (π × 900)) inches, at a 900 FPM design velocity
This uses the standard method. BuildingCalc gives CFM = BTU ÷ (1.08 × ΔT) with ΔT = 20 °F typical, and 400 CFM per ton — the two agree within about 11% at a 25 °F difference and match exactly at 27.8 °F, which is the temperature difference a real 3-ton system runs at (36,000 ÷ (1.08 × 1,200) = 27.8 °F). The duct formula is the standard area-from-flow calculation: at 900 FPM, 400 CFM needs 0.444 ft² of duct, which is a 9-inch round duct. The one judgement call is the velocity: 900 FPM is a quiet trunk velocity; branch ducts often run 1,000–1,200 FPM and come out one size smaller.
Worked example
A 12 × 15 ft room, 8 ft ceiling, 6 air changes per hour:
Volume: 12 × 15 × 8 = 1,440 ft³ (40.78 m³)
CFM: 1,440 × 6 ÷ 60 = 144 CFM (245 m³/h) — the same as 0.36 tons of cooling
Duct: 12 × √(4 × 144 ÷ (π × 900)) = 5.42 in → a 6 in round duct
Cost: 10 ft of 6 in duct at $5/ft = $50 + register ~$40 = $90
For a 3-ton air conditioner: CFM = 3 × 400 = 1,200 CFM (2,039 m³/h), duct 15.64 in → a 16 in round duct. And for a 36,000 BTU/hr load at a 25 °F difference: CFM = 36,000 ÷ (1.08 × 25) = 1,333 CFM — the 400 CFM/ton rule gives 1,200 CFM, and the two agree within about 11%.
How much does ductwork cost? (US, 2026)
Prices are 2026 US ranges from US retail listings and Angi installed-price guides (flexible duct per linear foot, installed). A register or grille is $20–$60 each. Check local prices before ordering.
| Round duct size | Typical price per ft |
|---|---|
| 6 in | $4–$6 |
| 8 in | $6–$8 |
| 10 in | $8–$10 |
| 12 in | $10–$12 |
| 14 in | $12–$14 |
| 16 in | $14–$16 |
| 18 in | $16–$18 |
| 20 in | $18–$20 |
| Register / grille | $20–$60 each |
Waste allowance
There is no waste percentage on a CFM calculation — the airflow is exact once the room or the tonnage is known. The allowance that matters is the duct run: add 10% to the duct length for bends and the connection at the register, and buy one extra register if the run serves two rooms.
Frequently asked questions
How many CFM do I need for a 12x12 room?
About 96 CFM at 4 air changes per hour (12 × 12 × 8 ft = 1,152 ft³ × 4 ÷ 60), or 144 CFM at 6 ACH. A bedroom is usually 4–6 ACH; a kitchen or bathroom 6–8.
How many CFM per ton of AC?
About 400 CFM per ton of cooling — the industry standard. A 3-ton system needs 1,200 CFM, a 5-ton system 2,000 CFM. Some systems run 350 CFM per ton for better humidity control, or 450 for more airflow.
How do you calculate CFM from BTU?
Divide the BTU load by 1.08 × the temperature difference across the coil: CFM = BTU/hr ÷ (1.08 × ΔT). A 36,000 BTU/hr load at a 25 °F difference needs 1,333 CFM. At 27.8 °F it matches the 400 CFM/ton rule exactly.
What size duct do I need for 400 CFM?
A 9-inch round duct at a 900 FPM design velocity (400 CFM ÷ 900 FPM = 0.444 ft² of area). Some charts show 8 inches, because they use a faster branch velocity of about 1,150 FPM — the air is the same, the velocity is higher and noisier.
How many CFM is 1 ACH?
It depends on the room volume: CFM = volume × ACH ÷ 60. A 12 × 15 × 8 ft room (1,440 ft³) is 24 CFM per air change per hour, so 6 ACH is 144 CFM.