200+ free tools. No sign-up. No hidden fees.Explore the toolkit ↗
Find a tool ↗

Home›BTU Calculator

BTU Calculator

How many BTUs does a room need — for cooling in summer and heating in winter? This calculator uses the standard rule of thumb (about 20 BTU per square foot for cooling, 40 for heating) and then adjusts it for your ceiling height, insulation, sun exposure, occupants and kitchen heat. The result is an estimate for planning — a licensed HVAC professional should confirm the final equipment size, and a whole-house load needs a proper Manual J calculation.

Calculate your BTUs

⚠︎ Sizing is an estimate only. Sizing must be confirmed by a licensed HVAC professional and comply with your local code. Improper sizing wastes energy and can damage equipment — never treat a calculator result as a final equipment selection.
Units:

The 20 / 40 BTU per square foot figures are rules of thumb for an 8 ft ceiling with average insulation. Each extra person beyond two adds about 600 BTU of cooling (body heat); a kitchen adds about 4,000 BTU from the oven and appliances. Heating needs no sun or kitchen adjustment — the sun helps in winter, and cooking heat is already in the room.

Your results

–
cooling load
–
heating load
–
cooling tons
–
cooling kW

How the BTU formula works

Air conditioners and heaters are rated in BTUs per hour. The industry rule of thumb starts from the floor area and adjusts for the things that change the load.

Cooling: BTU/hr = area × 20 × (ceiling ÷ 8) × insulation factor × sun factor + 600 × extra people + 4,000 if a kitchen

Heating: BTU/hr = area × 40 × (ceiling ÷ 8) × insulation factor

Tonnage: tons = cooling BTU/hr ÷ 12,000 — one ton of cooling is 12,000 BTU/hr

Kilowatts: kW = BTU/hr × 0.000293071

This uses the standard method, matching the published room-size table: a 200 sq ft room needs about 4,000 BTU of cooling and 8,000–10,000 BTU of heating; a 1,000 sq ft room needs about 20,000 BTU cooling and 40,000–44,000 BTU heating. The 20 / 40 factors already include a typical margin, so do not add another 10% on top. The one judgement call is the insulation factor: poor insulation (draughty, single glazing) is 1.3, average is 1.0, good insulation (sealed, double glazing) is 0.8.

Worked example

A 12 × 15 ft living room, 8 ft ceiling, average insulation, sunny, 2 occupants:

Area: 12 × 15 = 180 sq ft

Cooling: 180 × 20 × 1.0 × 1.1 = 3,960 BTU/hr (0.33 tons, 1.16 kW) → buy a 5,000 BTU window unit

Heating: 180 × 40 × 1.0 = 7,200 BTU/hr (2.11 kW) → buy an 8,000 BTU heater

Cost: window unit ~$300 + heater ~$100 = $400 equipment

For a 20 × 25 ft kitchen, 9 ft ceiling, poor insulation, sunny, 4 occupants: cooling = 500 × 20 × 1.125 × 1.3 × 1.1 + 1,200 + 4,000 = 21,288 BTU/hr (1.77 tons) → a 24,000 BTU (2-ton) mini-split, ~$3,500; heating = 500 × 40 × 1.125 × 1.3 = 29,250 BTU/hr → a 30,000 BTU heater, ~$3,500 — $7,000 equipment in total. And a 10 × 12 ft bedroom, 8 ft ceiling, good insulation, shady, 1 occupant: cooling = 120 × 20 × 0.8 × 0.9 = 1,728 BTU/hr → a 5,000 BTU unit (the smallest standard size), ~$300; heating = 120 × 40 × 0.8 = 3,840 BTU/hr → a 5,000 BTU heater, ~$100.

How much does heating and cooling equipment cost? (US, 2026)

Prices are 2026 US ranges from US retail listings and Angi installed-price guides. Installation is extra: about $150–$400 for a window unit, $1,500–$3,000 for a mini-split, $2,500–$6,500 for a furnace. Check local prices before ordering.

EquipmentTypical price
Window AC, 5,000–8,000 BTU$200–$400
Window AC, 10,000–12,000 BTU$300–$600
Mini-split, 12,000–18,000 BTU (installed)$2,500–$4,500
Mini-split, 24,000 BTU (installed)$3,500–$6,000
Space heater, 5,000–10,000 BTU$40–$150
Electric furnace / air handler, 30,000–60,000 BTU (installed)$2,500–$5,000
Gas furnace, 60,000–100,000 BTU (installed)$3,500–$6,500

Waste allowance

There is no waste percentage on a BTU calculation — the load is exact once the room is measured. The mistake to avoid is oversizing: a 24,000 BTU unit in a room that needs 4,000 BTU will short-cycle, leave the air clammy and wear out early. Buy the standard size just above the calculated load, never two sizes up.

Frequently asked questions

How many BTUs do I need for a 12x12 room?

About 2,880 BTU of cooling and 5,760 BTU of heating with average insulation and an 8 ft ceiling (144 sq ft × 20 and × 40). Buy a 5,000 BTU window unit for cooling — the smallest standard size — and a 6,000–8,000 BTU heater.

How many BTUs per square foot?

About 20 BTU per square foot for cooling and 40 for heating, at an 8 ft ceiling with average insulation. Poor insulation raises both by about 30%; good insulation cuts them by about 20%. A vaulted ceiling adds load in proportion to its height.

How many tons is 24000 BTU?

2 tons — one ton of cooling is 12,000 BTU/hr, so 24,000 ÷ 12,000 = 2. Standard residential sizes run 1.5, 2, 2.5, 3, 3.5, 4 and 5 tons.

What size AC do I need for 1000 sq ft?

About 20,000 BTU (1.7 tons) of cooling and 40,000 BTU of heating with average insulation — a 24,000 BTU (2-ton) mini-split covers the cooling. HowManyBTUs publishes the same figures: 20,000 cooling and 40,000–44,000 heating for 1,000 sq ft.

Is a bigger AC better?

No — an oversized air conditioner cools the room so fast it switches off before it has removed the humidity, leaving the air cold and clammy, and the constant starting and stopping wears the compressor out. Size to the load, not to the biggest unit you can afford.