Home›Boiler Size Calculator
Boiler Size Calculator
A boiler carries three different capacity numbers and they can differ by 40%: the net output it delivers to the radiators, the gross output after piping losses, and the input rating printed on the nameplate. Oversize it and it short-cycles and wastes fuel; undersize it and the house never gets warm on the coldest day. Enter the heat loss and the hot water demand to get all three numbers, the model to buy and the installed cost.
Calculate boiler size
Your results
How the boiler size formula works
Heat loss = floor area × BTU/sq ft × insulation factor · Hot-water load = 500 × GPM × temperature rise (°F) · Net I=B=R output = the larger of heat loss and hot-water load · Gross output = net × pickup factor (1.15 hot water, 1.333 steam) · Input rating = gross ÷ AFUE
Boilers carry three different capacity numbers and they can differ by 40% (4calculators.com). The building’s design heat loss sets the net I=B=R output the boiler must deliver — that is the rating to match when you shop. The piping and pickup allowance turns it into the gross output (1.15 for hot water, 1.333 for steam, the Institute of Boiler and Radiator Manufacturers allowance for distribution losses and warm-up), and the thermal efficiency turns that into the input rating printed on the nameplate. Domestic hot water is handled properly: an indirect tank on priority control shuts the heating zones off while the tank recovers, so the boiler only needs to cover the larger of the two loads — not their sum. A combi works the same way, taking the larger of heating and the continuous hot-water load (500 × GPM × rise). One source (simpledecisionmaker.onrender.com) adds the hot-water load to the heat load instead; this calculator follows the majority (4calculators.com, calcwall.com, dashcalculator.com) and takes the larger, because a boiler on priority control serves one load at a time.
Worked example
Worked example: 2,000 sq ft home, indirect tank, 95% AFUE
A 2,000 sq ft home at 40 BTU/hr/sq ft, average insulation, indirect hot-water tank on priority, 95% AFUE condensing boiler, 1.15 hot-water pickup factor:
- Design heat loss: 2,000 × 40 × 1.0 = 80,000 BTU/hr (23.4 kW)
- Hot-water load: 15,000 BTU/hr (priority tank)
- Net I=B=R output: the larger — 80,000 BTU/hr
- Gross output: 80,000 × 1.15 = 92,000 BTU/hr
- Input rating: 92,000 ÷ 0.95 = 96,842 BTU/hr — buy a 100,000 BTU/hr boiler
- Baseboard: 80,000 ÷ 550 = 145 lin ft at 180°F
- Flow: 80,000 ÷ (500 × 20) = 8.0 GPM
- Cost: 100,000 BTU/hr boiler installed $6,000-$9,500, midpoint $7,750
Cross-check: simpledecisionmaker.onrender.com gives the same 80,000 BTU/hr heat loss, 95,000 BTU/hr net (it adds the 15,000 DHW load), 109,250 gross and 115,000 input for this house — the difference is only the DHW treatment (see the formula section). A second check from calcwall.com: a 60,000 BTU/h load at 90% AFUE needs 66,667 BTU/h input, so an 80,000 BTU/h boiler — this calculator gives 69,000 gross and 76,667 input for the same load with the 1.15 pickup factor, and the same 80,000 model. A combi check: 2.5 GPM warmed 70°F needs 500 × 2.5 × 70 = 87,500 BTU/hr (calcwall.com says about 87,600).
An oversized boiler short-cycles, wastes fuel and wears out early. A Manual J load calculation beats any area rule — use the area method only to sanity-check a quote.
How much does a boiler cost? (US, 2026)
Typical 2026 US installed prices by boiler size (Angi, This Old House). Equipment alone is roughly half the installed figure; labour, venting, controls and disposal make up the rest.
| Boiler size (BTU/hr) | Home size | Installed cost (US, 2026) |
|---|---|---|
| 60,000 | Up to 1,200 sq ft | $4,000-$6,000 |
| 80,000 | 1,200-1,800 sq ft | $5,000-$8,000 |
| 100,000 | 1,800-2,500 sq ft | $6,000-$9,500 |
| 120,000+ | 2,500+ sq ft | $8,000-$12,000 |
| 2,000 sq ft home, 100,000 BTU/hr | — | ~$7,750 (midpoint) |
| US 2026 prices, checked November 2026. Sources: angi.com propane boiler installation cost 2026, thisoldhouse.com boiler replacement cost 2026, msrpguide.com boiler replacement cost 2026. | ||
Waste allowance
There is no waste percentage on a boiler size — the load is the load. The allowance to plan for is the piping and pickup factor: 1.15 for hot water, 1.333 for steam. It covers the heat the pipes lose on the way to the radiators and the extra heat needed to warm the system up from cold (the I=B=R allowance). Do not add a second safety margin on top of it — a boiler sized with pickup factor on top of a padded heat loss is an oversized boiler, and oversized boilers short-cycle.
Frequently asked questions
What size boiler do I need for a 2,000 sq ft house?
About 80,000 BTU/hr of heat loss at 40 BTU per square foot with average insulation — a 100,000 BTU/hr boiler at 95% AFUE. The honest answer needs a Manual J load calculation: the same house in a warm climate needs about 50,000 BTU/hr and in a severe cold climate about 110,000.
What is the difference between boiler input and output?
Input is the fuel firing rate on the nameplate; output is the heat the boiler actually delivers. A 100,000 BTU/hr input boiler at 95% AFUE delivers 95,000 BTU/hr gross, and after the 1.15 piping and pickup allowance the net I=B=R output is about 82,600 BTU/hr. Shop by the net output, not the input.
Does a combi boiler need to be bigger?
Yes for hot water, not for heating. A combi must warm tap water as fast as you draw it: 2.5 GPM warmed 70 degrees needs about 87,500 BTU/hr, which can exceed the heating load. Size a combi on the larger of the heating load and the hot-water load, not their sum.
What is the I=B=R pickup factor?
The Institute of Boiler and Radiator Manufacturers allowance for distribution losses and warm-up: 1.15 for hot-water systems, 1.333 for steam. It turns the net output the radiators need into the gross output the boiler must produce. Steam carries a much larger allowance because the piping and condensate must be heated before the radiators see steam.
Is an oversized boiler a problem?
Yes. An oversized boiler short-cycles — it fires, hits its set-point in minutes and shuts off — which wastes fuel, wears out the burner and controls, and leaves rooms unevenly heated. A boiler sized with a padded heat loss plus the pickup factor on top is an oversized boiler.