200+ free tools. No sign-up. No hidden fees.Explore the toolkit ↗
Find a tool ↗

Home›Sump Pump Calculator

Sump Pump Calculator

A sump pump is sized by two numbers that have nothing to do with each other: how fast water flows into the pit, and how high the pump must lift it. A pump that moves enough water at five feet of head can move half as much at fifteen. Enter the pit size and the rise rate to get the inflow, the required flow with a safety factor, the total dynamic head and the smallest pump class that actually delivers it — before the basement floods.

Calculate sump pump size

⚠︎ Estimate only. Plumbing work must comply with your local code (IPC/UPC in the US). Consult a licensed plumber before you buy or install anything — never treat a calculator result as code compliance.
Units:

Your results

661 GPH
inflow to pit
991 GPH
required flow
8.72 ft
total dynamic head
1/3 HP
smallest pump class
2,178 GPH
delivers at TDH
$180
pump cost (midpoint)

How the sump pump formula works

Gallons per inch = π × (diameter ÷ 2)² × 0.004329  ·  Inflow (GPM) = gallons per inch × rise rate (in/min)  ·  Required flow = inflow × 1.5 safety factor  ·  Total dynamic head = vertical lift + friction loss (Hazen-Williams, C = 150)  ·  Smallest pump = first pump whose curve delivers the required flow at the TDH

The inflow is measured, not guessed: time how fast the water rises in the pit during a heavy rain, and the pit’s diameter converts inches per minute into gallons per minute (ponderloop.com). The required flow is the inflow times a 1.5 safety factor — the standard recommendation from the pump makers, because a storm can always beat the one you measured. Total dynamic head is the vertical lift plus the friction loss in the discharge pipe, where each 90° elbow counts as 30 pipe diameters of extra length and a check valve as 100 (calcformula.com). The pump is then picked off its performance curve: a 1/3 HP pump moves 2,580 GPH at 5 ft of head but only 1,140 GPH at 15 ft, so the same pump is adequate at one head and inadequate at another.

Worked example

Worked example: 18 in pit, water rising 10 in/min, 8 ft lift

An 18 in sump pit with water rising 10 in/min during a heavy rain, 8 ft of lift, 20 ft of 1-1/2 in discharge pipe, 2 elbows, a check valve, 1.5x safety factor, 8 in of water at pump-on:

Cross-check: an independent calculator gives the same 1.10 gal/in for an 18 in pit and 661 GPH at 10 in/min, and the same 1/3 HP curve (2,580 GPH at 5 ft, 2,040 at 10 ft, 1,140 at 15 ft). A second check from calcformula.com: 16.5 GPM at 10 ft of lift needs a total dynamic head of 10.81 ft — this calculator gives the same head for those inputs. A third from ponderloop.com: an 18 in pit at 10 in/min is 11 GPM, and a 1,000 GPH pump at 10 ft of head is the recommendation for it.

A pump that is too big short-cycles and burns out its switch; a pump that is too small runs all night and the basement still floods. Size on the measured inflow, not the pump you already own.

How much does a sump pump cost? (US, 2026)

Typical 2026 US prices for sump pumps by class. A battery backup adds $200-$400 and is the single most valuable upgrade.

Pump classFlow at 10 ft headPrice (US, 2026)
1/3 HP2,040 GPH$120-$240
1/2 HP3,660 GPH$180-$320
3/4 HP4,500 GPH$250-$450
1 HP5,400 GPH$350-$600
Battery backup system—$200-$400
18 in pit, 10 in/min, 1/3 HP—~$180 (midpoint)
US 2026 prices, checked November 2026. Sources: ponderloop.com sump pump size calculator, US retail sump pump list prices.

Waste allowance

There is no waste percentage on a sump pump — the inflow is the inflow. The allowance to plan for is the 1.5x safety factor on the measured inflow: it covers the storm that beats the one you measured and the day the discharge pipe is partly frozen or clogged. In a heavy-rain area use 2.0x. A battery backup is not a luxury — it is what keeps the basement dry when the storm that floods it also takes the power out.

Frequently asked questions

What size sump pump do I need?

Measure the inflow: time how fast water rises in the pit during a heavy rain. An 18 in pit rising 10 in/min takes in 661 GPH, so with the 1.5x safety factor you need 991 GPH at the total dynamic head — a 1/3 HP pump at 8.72 ft of head.

How do I measure sump pump inflow?

Time the water rise in the pit during a heavy rain, then multiply by the gallons per inch of your pit: 1.10 gal/in for 18 in, 1.76 for 24 in, 2.65 for 30 in. A bucket test works too — 5 gallons in 30 seconds is 600 GPH of inflow.

What is total dynamic head?

The vertical lift from the pump to the discharge plus the friction loss in the discharge pipe. A 1/3 HP pump moves 2,580 GPH at 5 ft of head but only 1,140 GPH at 15 ft — the same pump is adequate at one head and inadequate at another.

Do I need a battery backup sump pump?

Yes, if the basement matters. The storm that floods a basement is the same storm that takes the power out. A battery backup costs $200-$400 and is the single most valuable upgrade on any sump system.

Why does my sump pump run all the time?

Either the inflow exceeds what the pump delivers at its head, or the pump is short-cycling on a float switch set too close to the water level. Check the rise rate first: if the inflow is higher than the pump’s delivery at the total dynamic head, the pump is undersized.