200+ free tools. No sign-up. No hidden fees.Explore the toolkit ↗
Find a tool ↗

Home›Pipe Volume Calculator

Pipe Volume Calculator

How much water is inside a length of pipe — for filling a system, dosing a treatment, draining a loop, or working out how long the hot water takes to arrive? This calculator works out the internal volume from the inside diameter and the length, in gallons, litres and cubic feet, with the weight of the water and the volume per foot. Pick a nominal pipe size and the schedule fills in the real inside diameter for you.

Calculate your pipe volume

⚠︎ Estimate only. Pipe and tank sizing must be confirmed by a licensed plumber and comply with your local plumbing code (IPC/UPC in the US). Never treat a calculator result as code compliance.
Units:

Always use the inside diameter, not the nominal size: a 2 in pipe is only 2.067 in inside on Schedule 40, and 1.939 in on Schedule 80. Copper tube is different again — 3/4 in Type L copper is 0.785 in inside. The schedule matters most on small pipe, where the wall is a large share of the diameter.

Your results

–
volume in US gallons
–
volume in litres
–
gallons per foot
–
fluid weight

How the pipe volume formula works

A pipe is a cylinder, so its volume is the inside cross-section area times the length.

Area: A = π × (ID ÷ 2)² — ID is the inside diameter in inches

Volume: V = A × length in cubic inches (length in feet × 12)

Gallons: US gallons = V ÷ 231 — 231 in³ per US gallon

Litres: litres = gallons × 3.78541  ·  cubic feet: ft³ = V ÷ 1,728

Field formula: gallons = 0.0408 × ID² × length (ft) — the plumber’s shortcut, same answer

This uses the standard method, verified against published tables: 2 in Schedule 40 (2.067 in ID) holds 0.1743 gallons per foot, so 100 ft holds 17.43 gallons; 1 in Schedule 40 (1.049 in ID) holds 0.0449 gallons per foot. The one judgement call is the inside diameter — nominal size is not the bore, and the schedule changes it: always look the ID up for the actual pipe you are buying.

Worked example

100 ft of 2 in Schedule 40 steel pipe (2.067 in inside diameter), water:

Area: π × (2.067 ÷ 2)² = π × 1.0685 = 3.356 in²

Volume: 3.356 × 100 × 12 = 4,027 in³

Gallons: 4,027 ÷ 231 = 17.43 US gallons (65.98 litres, 2.33 ft³)

Per foot: 0.1743 gal/ft — exactly the CalculatorsHub table value

Weight of water: 17.43 × 8.34 = 145.4 lb

Cost: 100 ft at $4.00/ft = $400 pipe

For a 50 ft hot-water run in 3/4 in Type L copper (0.785 in ID): area 0.484 in², volume 290 in³, 1.26 US gallons (4.8 litres) — the Engineer Underground example, which is why the hot water takes a few seconds to arrive. And 100 m of NPS 2 Schedule 40 (52.5 mm ID): 216 litres (57 US gallons), weighing 216 kg of water.

How much does pipe cost? (US, 2026)

Prices are 2026 US ranges from US retail listings per linear foot. Fittings add roughly 30–50% to the pipe cost on a typical run. Check local prices before ordering.

PipeTypical price per ft
PEX, 1/2 in$0.50–$1.00
PEX, 3/4 in$0.75–$1.50
PVC Schedule 40, 2 in$1.50–$3.00
PVC Schedule 40, 4 in$4.00–$7.00
Copper Type L, 3/4 in$3.00–$5.00
Copper Type L, 1 in$5.00–$8.00
Steel Schedule 40, 2 in$4.00–$7.00
Steel Schedule 40, 4 in$8.00–$12.00

Waste allowance

There is no waste percentage on a pipe volume calculation — the volume is exact once the diameter and length are known. The allowance that matters is the pipe length: add 10% to the run for cuts, bends and the fittings, and buy one extra length if the run has more than a few joints.

Frequently asked questions

How many gallons are in 100 feet of 2 inch pipe?

17.43 US gallons on Schedule 40 (2.067 in inside diameter) — 0.1743 gallons per foot. On Schedule 80 (1.939 in ID) it is 15.34 gallons. The weight of the water is 145.4 lb.

How do you calculate the volume of water in a pipe?

Work out the inside cross-section area (π × radius²) and multiply by the length, then divide by 231 for US gallons. The plumber’s shortcut is gallons = 0.0408 × inside diameter² × length in feet.

How much water does 1 inch pipe hold per foot?

0.0449 gallons per foot on Schedule 40 (1.049 in ID) — 4.49 gallons per 100 ft. On 1/2 in Schedule 40 it is 0.0158 gallons per foot, and on 3/4 in it is 0.0277.

What is the inside diameter of 2 inch Schedule 40 pipe?

2.067 inches (52.5 mm). The nominal size is not the bore: 2 in Schedule 80 is 1.939 in inside, and 2 in copper is different again. Always look the ID up for the schedule you are buying.

How long does hot water take to arrive?

It depends on the volume in the pipe: a 50 ft run of 3/4 in Type L copper holds 1.26 gallons, so at 2 GPM the hot water takes about 38 seconds to reach the tap. A recirculation pump or a smaller pipe cuts the wait.