200+ free tools. No sign-up. No hidden fees.Explore the toolkit ↗
Find a tool ↗

Home›Plumbing Pipe Size Calculator

Plumbing Pipe Size Calculator

A water supply line is sized by flow, not by the fixtures it passes. The code method is Hunter’s curve: every fixture counts as a number of water supply fixture units, the units add up, and the curve converts them to a probable peak flow. Too small a pipe and the pressure collapses when two fixtures run at once; too large and it costs more and wastes hot water. Enter the fixtures to get the pipe size, the velocity, the pressure loss and the pressure at the fixture.

Calculate plumbing pipe size

⚠︎ Estimate only. Plumbing work must comply with your local code (IPC/UPC in the US). Consult a licensed plumber before you buy or install anything — never treat a calculator result as code compliance.
Units:

Your results

17.1 WSFU
fixture units
18.2 GPM
probable peak flow
1 in copper
minimum pipe size
7.1 ft/s
velocity
9.2 psi/100 ft
friction loss
41.9 psi
pressure at fixture

How the plumbing pipe size formula works

WSFU = sum of (fixture count × fixture units)  ·  Probable flow (GPM) = Hunter’s curve on WSFU  ·  Velocity (ft/s) = 0.4085 × GPM ÷ ID²  ·  Friction (psi/100 ft) = 0.2083 × (100/C)1.85 × GPM1.852 ÷ ID4.8655 × 0.4335 (Hazen-Williams, C = 140; the 0.4335 converts feet of head to psi)  ·  Pressure at fixture = supply − rise × 0.4335 − friction × equivalent length

Hunter’s curve (1928, still the basis of IPC Table E103.3(3)) converts fixture units to the probable peak demand — the idea being that not every fixture runs at once, so 17 fixture units needs 18.2 GPM rather than the sum of the fixture flows. The pipe is then sized on the smallest diameter that keeps the velocity at or below 8 ft/s, the IPC limit for water supply piping; friction loss is checked against the 20 psi minimum pressure at the fixture, not capped by it (buildingcalc.com). The fittings are counted as an extra 50% of pipe length — a common rule of thumb that roughly matches summing the equivalent lengths of a typical run of elbows and tees. Velocity matters because it decides noise and water hammer: a 1/2 in pipe carrying 5.8 GPM is already at 8 ft/s, while 1 in carries 20.6 GPM at the same speed (pipingcalculators.com).

Worked example

Worked example: house with 3 WCs, 3 lavatories, 2 showers, tub, kitchen, washer, dishwasher

A house with 3 water closets, 3 lavatories, 2 showers, 1 bathtub, 1 kitchen sink, 1 clothes washer and 1 dishwasher, copper Type L, 100 ft of pipe to the furthest fixture, 60 psi supply, 10 ft rise:

Cross-check: pipingcalculators.com gives 14.8 fixture units as 17.4 GPM and 1 in copper at 6.8 ft/s for a similar house; this calculator’s curve lands in the same place. A second check from calcformula.com: 10 GPM through 3/4 in copper Type L gives 6.6 ft/s, 11.17 psi/100 ft and 38.9 psi at the fixture on a 150 ft run — this calculator gives 6.63 ft/s, 11.2 psi/100 ft and 38.9 psi for the same inputs. A third from mahelak.com: 5 WSFU is 9.4 GPM and 10 WSFU is 14.6 GPM, which this calculator matches exactly.

Only the velocity caps a supply line at 8 ft/s; pressure loss is checked, not capped. A bigger pipe costs more but also costs less in pump energy and noise.

How much does water supply pipe cost? (US, 2026)

Typical 2026 US material prices per foot for water supply pipe, plus a $250 fittings and labour allowance for a single run.

PipePrice per ft (US, 2026)
Copper Type L, 1/2 in$1.50
Copper Type L, 3/4 in$2.20
Copper Type L, 1 in$3.00
PEX, 1/2 in$0.45
PEX, 3/4 in$0.65
PEX, 1 in$1.00
Fittings and labour, one run$250
150 ft of 1 in copper, installed~$550
US 2026 prices, checked November 2026. Sources: US retailer copper and PEX list prices, mahelak.com pipe size calculator, pipingcalculators.com water pipe size calculator.

Waste allowance

There is no waste percentage on pipe sizing — the flow is the flow. The allowance to plan for is equivalent length: every elbow, tee and valve adds friction just like extra pipe, so the fitting allowance is 50% of the straight length in this calculator. On a run with many turns — a bathroom group with four elbows and two tees — count the fittings properly or the pressure at the fixture will come in low.

Frequently asked questions

What size water supply pipe do I need for a house?

A typical 3-bathroom house totals about 17 fixture units, which Hunter’s curve converts to about 18 GPM — that needs a 1 in copper or PEX main. A 2-bathroom house at about 14 fixture units needs the same 1 in main. The main is usually one size up from the largest branch.

What is a water supply fixture unit (WSFU)?

A fixture unit is the code’s measure of how much demand a fixture places on the water supply: a flush-tank water closet is 2.2, a lavatory is 0.7, a shower, bathtub, kitchen sink, washer and dishwasher are 1.4 each. They add up, and Hunter’s curve converts the total to a probable peak flow.

What is the maximum water velocity in a pipe?

8 ft/s is the IPC limit for water supply piping. Faster water is noisy, wears out fittings and can hammer. A 1/2 in pipe reaches 8 ft/s at 5.8 GPM, 3/4 in at 12.1 GPM and 1 in at 20.6 GPM.

How much pressure do I need at a fixture?

At least 20 psi at the fixture is the code minimum, and most fixtures are happiest at 40-60 psi. Above 80 psi the IPC requires a pressure-reducing valve (IPC 604.8).

Is PEX or copper better for water supply?

Both size by the same fixture-unit method and both have a Hazen-Williams C of 130. PEX is cheaper, faster to install and quieter; copper tolerates hot water and UV better and holds its shape. PEX has a smaller inside diameter for the same nominal size, so it can need one size up on a long run.