Home›Beam Deflection Calculator
Beam Deflection Calculator
Work out exactly how far a beam sags under load — in inches and millimetres — and check it against the L/360 floor limit and the L/240 roof limit. A beam can be strong enough and still sag too much: deflection is a separate check from strength, and it is the one that cracks plaster and bounces floors.
Calculate your beam deflection
Common I values (in⁴): 2×8 = 47.63, 2×10 = 98.93, 2×12 = 177.98, 4×10 = 230.84, 4×12 = 415.28, LVL 1¾×9¼ = 115.42. I = b × d³ ÷ 12 for a rectangular section. Deflection grows with the fourth power of the span — doubling the span multiplies the sag sixteen times.
Your results
How the beam deflection formula works
Deflection is how far the middle of a beam drops under load. For the two cases that cover most DIY work — a load in the middle, and a load spread evenly over the whole span — the formulas are simple, and both need the same two section properties: the modulus E (how stiff the material is) and the moment of inertia I (how efficiently the shape resists bending).
Central point load: δ = P × L³ ÷ (48 × E × I)
Uniform load: δ = 5 × w × L⁴ ÷ (384 × E × I) — w in force per unit length, L in the same unit as I
Cantilever, tip load: δ = P × L³ ÷ (3 × E × I)
Limit: L/360 for floors with plaster or tile, L/240 for roofs and general framing, L/480 where finishes are sensitive
Moment of inertia, rectangle: I = b × d³ ÷ 12 — depth matters cubed, so a 2×10 is 2.1× stiffer than a 2×8
This is the Omni / CalculatorSoup / Zencalcy method, and it reproduces their published examples exactly: a 10 ft span with a 2,000 lb central point load on a steel I-beam (I = 100 in⁴, E = 29,000,000 psi) deflects 0.025 in — well inside the L/360 limit of 0.33 in (Zencalcy). A 4×10 Douglas Fir-Larch beam (I = 230.84 in⁴, E = 1,900,000 psi) over 12 ft under 200 lb/ft deflects 0.213 in against a 0.400 in limit (OnlyCalculators). The limit is a serviceability rule, not a strength rule — a beam can pass bending and still fail deflection.
Worked example
A 4×10 Douglas Fir-Larch beam, 12 ft span, carrying a uniform load of 200 lb/ft (I = 230.84 in⁴, E = 1,900,000 psi), checked against L/360:
Load per inch: w = 200 ÷ 12 = 16.67 lb/in; span = 12 × 12 = 144 in
δ = 5 × 16.67 × 144⁴ ÷ (384 × 1,900,000 × 230.84) = 0.213 in (5.4 mm)
Limit: 144 ÷ 360 = 0.400 in — the beam uses 53% of its limit: PASS
Cost: 12 ft × $2.50 per lin ft = $30
A 10 ft steel I-beam (I = 100 in⁴) with a 2,000 lb point load at midspan deflects 2,000 × 120³ ÷ (48 × 29,000,000 × 100) = 0.025 in — 7% of the 0.333 in limit. And the same 4×10 wood beam over a 16 ft span under the same 200 lb/ft deflects 0.213 × (16/12)⁴ = 0.673 in — over the 0.533 in limit, so it fails at 16 ft. That is the fourth-power rule in action: a third more span, more than triple the sag.
How much do beams cost? (US, 2026)
Prices are 2026 US ranges from Home Depot / Lowe’s listings. Steel is priced per foot for common sizes; LVL is sold by the linear foot. Check local prices before ordering.
| Beam | Typical price per lin ft |
|---|---|
| 2×8 sawn lumber | $0.80–$1.20 |
| 2×10 sawn lumber | $1.20–$1.80 |
| 2×12 sawn lumber | $1.80–$2.50 |
| 4×10 sawn lumber | $2.50–$3.50 |
| LVL 1¾ × 9¼ in | $8–$12 |
| LVL 1¾ × 11⅞ in | $10–$14 |
| Steel W8 × 10 | $25–$40 |
Waste allowance
There is no waste allowance on this tool — a beam is a single exact length, not a bulk material. The number that matters is the stock length: sawn lumber comes in 2 ft increments (8, 10, 12, 14, 16 ft), so buy the next stock length up from your span plus bearing at each end (at least 3 in of bearing, 1½ in minimum).
Frequently asked questions
How much deflection is allowed in a beam?
For floors with plaster or tile, the usual limit is L/360 — the span in inches divided by 360. A 12 ft span allows 0.400 in. Roofs and general framing use L/240 (0.600 in at 12 ft), and sensitive finishes use L/480 (0.300 in at 12 ft). These are serviceability limits, not strength limits.
What is the beam deflection formula?
For a central point load: deflection = P × L³ ÷ (48 × E × I). For a uniform load over the whole span: deflection = 5 × w × L⁴ ÷ (384 × E × I). P is the load, L the span, E the material modulus and I the moment of inertia of the section.
How much will a 12 ft beam sag under 200 lb/ft?
A 4x10 Douglas Fir-Larch beam (I = 230.84 in⁴, E = 1,900,000 psi) over 12 ft under 200 lb/ft deflects 0.213 in — inside the L/360 limit of 0.400 in. The same beam at 16 ft deflects 0.673 in and fails the 0.533 in limit.
Why does my beam sag if it is strong enough?
Strength and stiffness are different checks. A beam can carry the load without breaking (bending stress below the allowable) and still deflect too much, because deflection depends on E × I while strength depends on the section modulus S. Deeper sections fix deflection faster than they fix strength.
What is the moment of inertia I for a 2x10?
For a rectangular section I = b × d³ ÷ 12, using actual dimensions. A 2x10 is actually 1.5 × 9.25 in, so I = 1.5 × 9.25³ ÷ 12 = 98.93 in⁴. A 2x8 is 47.63 in⁴ and a 2x12 is 177.98 in⁴.