Home›Header & Beam Span Calculator
Header & Beam Span Calculator
Work out what size header a door or window opening needs — by span, tributary width, load and material. The check is real beam maths: bending and deflection. This is an estimate — always verify with an engineer or your local code.
Calculate your header size
Important: this is a sizing estimate from published span tables and beam formulas (IRC R602.7, 4Calculators, BuildCalc). It is not an engineering design. For load-bearing walls, wide openings or two storeys, have a structural engineer confirm the size. Tributary width is half the span of the floor or roof on each side — for a 24 ft wide house, the middle bearing wall carries 12 ft.
Your results
How the header sizing formula works
A header is a short beam. It must pass two checks: it must be strong enough not to break (bending), and stiff enough not to sag (deflection).
Design span: clear opening + 3 in bearing (1½ in on each end)
Uniform load: w = tributary width (ft) × area load (psf) — roof only 35 psf, roof + 1 floor 75 psf, roof + 2 floors 115 psf
Max moment: M = wL² ÷ 8 · Reaction: R = wL ÷ 2
Required section modulus: S = M × 12 ÷ Fb′ — Fb′ = Fb × 1.15 (load-duration factor): SPF 900 × 1.15 = 1035 psi, LVL 2900 psi
Required inertia: I = 5wL⁴ ÷ (384 × E × Δ), Δ = L ÷ 240
Jack studs: 1 per side up to 6 ft, 2 for 6–12 ft, 3 over 12 ft
This is the 4Calculators / BuildCalc / NovaCalculator method, and it reproduces their worked examples: a 6 ft opening, 12 ft tributary width, roof only — w = 420 lb/ft, M = 2050.8 lb-ft, S_req = 23.78 in³, I_req = 28.84 in⁴ — and the smallest passing section is (2) 2×8 (S 26.28, I 95.3). The IRC R602.7 span tables (BuildCalc) agree: (2) 2×6 to 4 ft, (2) 2×8 to 6 ft, (2) 2×10 to 8 ft, (2) 2×12 to 10 ft for a roof-only load. A second check: 6 ft, 12 ft tributary, 45 psf, Douglas fir-larch (Fb 850) gives S_req 32.4 with the load-duration factor — (2) 2×10, the same section NovaCalculator finds (their published S_req of 37.2 uses Fb without the factor). And an 8 ft garage opening with two floors above needs S_req ~159 in³ — no sawn-lumber section passes; LVL or steel is required.
Worked example
A 6 ft opening in an exterior wall, 12 ft tributary width, roof only (35 psf), SPF No. 2:
Design span: 6 ft + 3 in = 6.25 ft
Uniform load: 12 × 35 = 420 lb/ft
Max moment: 420 × 6.25² ÷ 8 = 2050.8 lb-ft
Required S: 2050.8 × 12 ÷ 1035 = 23.78 in³; required I: 28.84 in⁴
Smallest passing: (2) 2×8 (S 26.28, I 95.3) — 1 jack stud per side
A 4 ft window opening with the same load needs (2) 2×6. A 6 ft opening with a floor above (75 psf) needs (2) 2×10. An 8 ft garage opening with two floors above (115 psf, 14 ft tributary) needs S_req ~159 in³ — no sawn lumber passes; use LVL or steel and an engineer’s design.
How much does a header cost? (US, 2026)
Prices are 2026 US ranges from Home Depot / Lowe’s listings. An LVL costs roughly twice a sawn-lumber header of the same size but spans further. Check local prices before ordering.
| Item | Typical price |
|---|---|
| (2) 2×6 header, 6 ft | $15–$25 |
| (2) 2×8 header, 6 ft | $20–$35 |
| (2) 2×10 header, 8 ft | $30–$50 |
| (2) 2×12 header, 10 ft | $40–$70 |
| LVL 1¾ × 11⅞ in, per lin ft | $8–$12 |
| Jack stud (2×4 × 8 ft) | $3–$5 each |
| Structural engineer review | $300–$800 |
Waste allowance
There is no waste allowance on this tool — headers are sized, not ordered by quantity. Buy the header lumber in the stock length that covers the opening plus bearing (opening + at least 3 in), and buy one jack stud per side plus a king stud each side. If the calculated size is at the very limit of the next smaller section, step up a size: lumber varies, and a header is the worst place to save $10.
Frequently asked questions
What size header do I need for a 6 foot opening?
For a 6 ft opening with a roof only above it (35 psf, 12 ft tributary width), a (2) 2x8 SPF header passes — required section modulus 23.78 in³ against 26.28 in³ available. With a floor above, step up to (2) 2x10. Always confirm with your local code and an engineer for load-bearing walls.
How many jack studs for a header?
One jack stud per side for openings up to 6 ft, two per side for 6–12 ft, and three per side over 12 ft. Each jack stud sits under the header end and carries the reaction to the floor; a king stud runs full height beside it.
What is tributary width?
Tributary width is the width of floor or roof the header carries — half the span on each side of the wall. For a 24 ft wide house with a bearing wall in the middle, the middle wall carries 12 ft of tributary width. Measure to the next support, not to the edge of the house.
Can I use LVL instead of a sawn header?
Yes — LVL (laminated veneer lumber) is stronger and stiffer than sawn lumber, so it spans further at the same depth. A single 1¾ in LVL at 11⅞ in deep passes where a (2) 2x10 is needed. LVL costs roughly twice as much per foot but is the standard choice for openings over 8 ft.
Do I need a header over a non-load-bearing wall?
A non-load-bearing wall still needs a header over doors and windows to carry the studs above the opening and give the drywall something to fasten to — but it can be a single flat 2x4 or a (2) 2x4 header, since it carries almost no load. The sizing check on this page is for load-bearing walls.